This shop charger has two independent charging systems of 2Amps that are able to desulfate, charge, maintain & initialize new batteries using the 12 hour program. Simply connect a battery and the rest is automatic. 2 x 12V OR 1 x24V system.

Initializes new MF batteries within 12h
For 2 x 12V batteries or 1 x 24V system
Ampmatic automatic current control
Professional test & maintenance cycle
Optimizes battery power and life
More info ...

RETAIL
$699.90

This 8-bank shop charger can desulfate, recover, charge, test, & maintain up to
8 x batteries simultaneously and is ideal for maintaining 6V & 12V batteries in
the off season. Simply connect a
battery and the rest is automatic.

For 6V & 12V lead-acid batteries
Auto detection & recovery of batteries
Charges new batteries within 12 to 24 hours
Tests & verifies charge retention by battery
More info ...
Video Reviews

Initializes new MF batteries within 1 hour

Select NEW and a battery receives the correct initialization charge within 1 hour.

MAX charging time is 1 hour with maximum current automatically set at 4A.
Battery impedance dynamically changes as charge is delivered to the battery.

The Ampmatic program varies current according to battery impedance to bring the battery to full charge as quick as possible without ever overcharging the battery during the first charge cycle.

Powerful 2 or 4Amps bulk charge programs

The USED program allows optional selection between two sizes of battery (<10Ah>) and the rest is automatically done for you.

MAX charging time is 12 hours with the program moving to maintenance if left connected.

Select : 2A for batteries 10Ah and less 4A for batteries 10Ah+
Battery impedance dynamically changes as charge is delivered to the battery.

Bulk mode - current is controlled by the Ampmatic program until the battery voltage has risen to 14.3V.

Ampmatic automatic current control

The Ampmatic program varies current according to battery impedance to bring the battery to full charge as quick as possible without ever overcharging.
The MAX current setting limits total charge into the battery in case an aged or neglected battery has suffered electro-mechanical damage that significantly altered battery impedance.
Battery power is optimized during bulk, absorption & cell balancing charge modes by the micro processor controlled AMPMATIC program, a unique feature that automatically ensures the battery receives optimal current every second, and then tests to verify charge retention.

Professional test & maintenance cycle

Test period : Initial test: 30 minutes - Extended ‘cool down’ test: 12 hours.
Charging is suspended and the voltage is monitored.
If only the green LED (voltage above 12.7V) is flashing after 30 minutes the test is extended to12hours.
The extended test will expose suspect batteries that may seem to hold charge (following recovery), but lose power due to irreversible internal damage once the temperature lowers down to normal.
AGM batteries are expected to remain above 12.7V (green LED).
STD batteries are expected to remain above 12.6V (green / yellow LED).
Charge maintenance: during alternate 30 minute periods, at a float limit of 13.6V the battery is offered whatever charge current it needs to sustain it against any small connected loads or power leakage and against natural self discharge.
OptiMate PRO-S can stay connected to the battery indefinitely and the battery will be safe & 100% charged.

Optimizes battery power and life

In the absorption & cell equalization mode - for 10 minutes the voltage cycles between 13.6V & 14.3V as the Ampmatic program varies the current. This cyclic action effectively rebalances used battery cells whilst remaining below the natural gassing level of the acid mixture, ensuring that no pressure build up occurs in sealed batteries and overflow in std filler cap batteries is eliminated (if the battery was not overfilled prior to charging). If during the 5 minute verification mode the current demand from the battery remains high charging returns to absorption / equalization mode.
Battery power is optimized during bulk, absorption & cell balancing charge modes by the micro processor controlled AMPMATIC program, a unique feature that automatically ensures the battery receives optimal current every second, and then tests to verify charge retention.

Charging Amps

4Amps of constant current available from 0.5V to 14.3V on each of 4 banks.
Ampmatic control adjusts charge current to match the battery characteristics.
NEW selection - battery receives the correct initialization charge within 1 hour.
Maximum charging time is 1 hour with maximum current automatically set at 4A.
Battery impedance dynamically changes as charge is delivered to the battery.
USED select 2 or 4Amps - allows optional selection between two sizes of battery (<10Ah>) and the rest is automatically done for you.
Maximum charging time is 12 hours with the program moving to maintenance if left connected.
Select : 2A for batteries 10Ah and less / 4A for batteries 10Ah+

Charging Stages

Pre-qualification test / 3 types of desulfation recovery for different batteries and conditions / Bulk charge / Absorption & equalization / Charge verification / Voltage retention test / Maintenance program.

Desulfation Stages

All batteries lose charge when stored, discharge is speeded up when the battery is in the vehicle. Sulfation develops if a battery is left discharged for too long. Sulfation causes the battery to lose voltage and capacity, and the ability to accept a charge. The lost capacity cannot be returned by a standard smart charger, instead it quickly and incorrectly shows the battery as fully charged. OptiMate PROS detects sulfation, then applies "first aid" to recover the battery - TURBO* controlled high voltage at low current for extreme sulfation to low voltage pulsing sulfation for batteries in the vehicle - for up to 2hours. When the battery is ready to accept charge, bulk charge starts. During long term charge maintenance mode a frequent desulfating pulse prevents sulfation from re-occurring, *The TURBO desulfation stage works best with the battery disconnected from the vehicle, it is automatically inhibited if vehicle electronics is detected.

Microprocessor

The OptiMate PRO4 is microprocessor controlled which always ensures correct program selection with optimum results and advanced Ampmatic charge rate adjustment control.

Test Results

Test period : Initial test: 30 minutes - Extended ‘cool down’ test: 12 hours.
Charging is suspended and the voltage is monitored.
If only the green LED (voltage above 12.7V) is flashing after 30 minutes the test is extended to12hours.
The extended test will expose suspect batteries that may seem to hold charge (following recovery), but lose power due to irreversible internal damage once the temperature lowers down to normal.
AGM batteries are expected to remain above 12.7V (green LED).
STD batteries are expected to remain above 12.6V (green / yellow LED).
Charge maintenance: during alternate 30 minute periods, at a float limit of 13.6V the battery is offered whatever charge current it needs to sustain it

Ideal for

Recommended for all 12V lead-acid batteries up to 40Ah.

OptiMate Pro-S

Initializes new MF batteries within 1 hour

Select NEW and a battery receives the correct initialization charge within 1 hour.

MAX charging time is 1 hour with maximum current automatically set at 4A.
Battery impedance dynamically changes as charge is delivered to the battery.

The Ampmatic program varies current according to battery impedance to bring the battery to full charge as quick as possible without ever overcharging the battery during the first charge cycle.

OptiMate Pro-S

Powerful 2 or 4Amps bulk charge programs

The USED program allows optional selection between two sizes of battery (<10Ah>) and the rest is automatically done for you. MAX charging time is 12 hours with the program moving to maintenance if left connected.
Select : 2A for batteries 10Ah and less 4A for batteries 10Ah+
Battery impedance dynamically changes as charge is delivered to the battery.
Bulk mode - current is controlled by the Ampmatic program until the battery voltage has risen to 14.3V.

OptiMate Pro-S

Ampmatic automatic current control

The Ampmatic program varies current according to battery impedance to bring the battery to full charge as quick as possible without ever overcharging.
The MAX current setting limits total charge into the battery in case an aged or neglected battery has suffered electro-mechanical damage that significantly altered battery impedance.
Battery power is optimized during bulk, absorption & cell balancing charge modes by the micro processor controlled AMPMATIC program, a unique feature that automatically ensures the battery receives optimal current every second, and then tests to verify charge retention.

OptiMate Pro-S

Professional test & maintenance cycle

Test period : Initial test: 30 minutes - Extended ‘cool down’ test: 12 hours.
Charging is suspended and the voltage is monitored.
If only the green LED (voltage above 12.7V) is flashing after 30 minutes the test is extended to12hours.
The extended test will expose suspect batteries that may seem to hold charge (following recovery), but lose power due to irreversible internal damage once the temperature lowers down to normal.
AGM batteries are expected to remain above 12.7V (green LED).
STD batteries are expected to remain above 12.6V (green / yellow LED).
Charge maintenance: during alternate 30 minute periods, at a float limit of 13.6V the battery is offered whatever charge current it needs to sustain it against any small connected loads or power leakage and against natural self discharge.
OptiMate PRO-S can stay connected to the battery indefinitely and the battery will be safe & 100% charged.

OptiMate Pro-S

Optimizes battery power and life

In the absorption & cell equalization mode - for 10 minutes the voltage cycles between 13.6V & 14.3V as the Ampmatic program varies the current. This cyclic action effectively rebalances used battery cells whilst remaining below the natural gassing level of the acid mixture, ensuring that no pressure build up occurs in sealed batteries and overflow in std filler cap batteries is eliminated (if the battery was not overfilled prior to charging). If during the 5 minute verification mode the current demand from the battery remains high charging returns to absorption / equalization mode.
Battery power is optimized during bulk, absorption & cell balancing charge modes by the micro processor controlled AMPMATIC program, a unique feature that automatically ensures the battery receives optimal current every second, and then tests to verify charge retention.

OptiMate Pro-S

Charging Amps

4Amps of constant current available from 0.5V to 14.3V.
Ampmatic control adjusts charge current to match the battery characteristics.
NEW selection - battery receives the correct initialization charge within 1 hour.
Maximum charging time is 1 hour with maximum current automatically set at 4A.
Battery impedance dynamically changes as charge is delivered to the battery.
USED select 2 or 4Amps - allows optional selection between two sizes of battery (<10Ah>) and the rest is automatically done for you.
Maximum charging time is 12 hours with the program moving to maintenance if left connected.
Select : 2A for batteries 10Ah and less / 4A for batteries 10Ah+

OptiMate Pro-S

Charging Stages

Pre-qualification test / 3 types of desulfation recovery for different batteries and conditions / Bulk charge / Absorption & equalization / Charge verification / Voltage retention test / Maintenance program.

OptiMate Pro-S

Desulfation Stages

All batteries lose charge when stored, discharge is speeded up when the battery is in the vehicle. Sulfation develops if a battery is left discharged for too long. Sulfation causes the battery to lose voltage and capacity, and the ability to accept a charge. The lost capacity cannot be returned by a standard smart charger, instead it quickly and incorrectly shows the battery as fully charged. OptiMate PROS detects sulfation, then applies "first aid" to recover the battery - TURBO* controlled high voltage at low current for extreme sulfation to low voltage pulsing sulfation for batteries in the vehicle - for up to 2hours. When the battery is ready to accept charge, bulk charge starts. During long term charge maintenance mode a frequent desulfating pulse prevents sulfation from re-occurring, *The TURBO desulfation stage works best with the battery disconnected from the vehicle, it is automatically inhibited if vehicle electronics is detected.

OptiMate Pro-S

Microprocessor

The OptiMate PROS is microprocessor controlled which always ensures correct program selection with optimum results and advanced Ampmatic charge rate adjustment control.

OptiMate Pro-S

Test Results

Test period : Initial test: 30 minutes - Extended ‘cool down’ test: 12 hours.
Charging is suspended and the voltage is monitored.
If only the green LED (voltage above 12.7V) is flashing after 30 minutes the test is extended to12hours.
The extended test will expose suspect batteries that may seem to hold charge (following recovery), but lose power due to irreversible internal damage once the temperature lowers down to normal.
AGM batteries are expected to remain above 12.7V (green LED).
STD batteries are expected to remain above 12.6V (green / yellow LED).
Charge maintenance: during alternate 30 minute periods, at a float limit of 13.6V the battery is offered whatever charge current it needs to sustain it

OptiMate Pro-S

Ideal for

Recommended for all 12V lead-acid batteries up to 40Ah.

OptiMate Pro-2

Initializes new MF batteries within 12 hours

Includes the new AMPMATIC program that automatically controls current and enables cell equalization for initialization of new batteries over 12 hours.
Tests and verifies charge retention by battery.

OptiMate Pro-2

Charge 2 x 12V batteries individually or together as a 24V system

Both banks use the 12 hour program. MAX charging time is 12 hours with the program moving to maintenance if left connected.
Battery impedance dynamically changes as charge is delivered to the battery.
The Ampmatic program varies current according to battery impedance to bring the battery to full charge as quick as possible. The MAX current setting limits total charge into the battery in case an aged or neglected battery has suffered electro-mechanical damage that significantly altered battery impedance.

OptiMate Pro-2

Ampmatic automatic current control

The Ampmatic program varies current according to battery impedance to bring the battery to full charge as quick as possible without ever overcharging.
The MAX current setting limits total charge into the battery in case an aged or neglected battery has suffered electro-mechanical damage that significantly altered battery impedance.
Battery power is optimized during bulk, absorption & cell balancing charge modes by the micro processor controlled AMPMATIC program, a unique feature that automatically ensures the battery receives optimal current every second, and then tests to verify charge retention.

OptiMate Pro-2

Professional test & maintenance cycle

Test period : Initial test: 30 minutes - Extended ‘cool down’ test: 12 hours.
Charging is suspended and the voltage is monitored.
If only the green LED (voltage above 12.7V) is flashing after 30 minutes the test is extended to12hours.
The extended test will expose suspect batteries that may seem to hold charge (following recovery), but lose power due to irreversible internal damage once the temperature lowers down to normal.
AGM batteries are expected to remain above 12.7V (green LED).
STD batteries are expected to remain above 12.6V (green / yellow LED).
Charge maintenance: during alternate 30 minute periods, at a float limit of 13.6V the battery is offered whatever charge current it needs to sustain it against any small connected loads or power leakage and against natural self discharge.
OptiMate PRO-S can stay connected to the battery indefinitely and the battery will be safe & 100% charged.

OptiMate Pro-2

Optimizes battery power and life

In the absorption & cell equalization mode - for 10 minutes the voltage cycles between 13.6V & 14.3V as the Ampmatic program varies the current. This cyclic action effectively rebalances used battery cells whilst remaining below the natural gassing level of the acid mixture, ensuring that no pressure build up occurs in sealed batteries and overflow in std filler cap batteries is eliminated (if the battery was not overfilled prior to charging). If during the 5 minute verification mode the current demand from the battery remains high charging returns to absorption / equalization mode.
Battery power is optimized during bulk, absorption & cell balancing charge modes by the micro processor controlled AMPMATIC program, a unique feature that automatically ensures the battery receives optimal current every second, and then tests to verify charge retention.

OptiMate Pro-2

Charging Amps

2Amps of constant current available from each bank.
Initializes new MF batteries within 12 hours
Ampmatic control adjusts charge current to match the battery characteristics.
Battery impedance dynamically changes as charge is delivered to the battery.
Maximum charging time is 12 hours with the program moving to maintenance if left connected.

OptiMate Pro-2

Charging Stages

Pre-qualification test / 3 types of desulfation recovery for different batteries and conditions / Bulk charge / Absorption & equalization / Charge verification / Voltage retention test / Maintenance program.

OptiMate Pro-2

Desulfation Stages

All batteries lose charge when stored, discharge is speeded up when the battery is in the vehicle. Sulfation develops if a battery is left discharged for too long. Sulfation causes the battery to lose voltage and capacity, and the ability to accept a charge. The lost capacity cannot be returned by a standard smart charger, instead it quickly and incorrectly shows the battery as fully charged. OptiMate PROS detects sulfation, then applies "first aid" to recover the battery - TURBO* controlled high voltage at low current for extreme sulfation to low voltage pulsing sulfation for batteries in the vehicle - for up to 2hours. When the battery is ready to accept charge, bulk charge starts. During long term charge maintenance mode a frequent desulfating pulse prevents sulfation from re-occurring, *The TURBO desulfation stage works best with the battery disconnected from the vehicle, it is automatically inhibited if vehicle electronics is detected.

OptiMate Pro-2

Microprocessor

The OptiMate PRO2 is microprocessor controlled which always ensures correct program selection with optimum results and advanced Ampmatic charge rate adjustment control.

OptiMate Pro-2

Test Results

Test period : Initial test: 30 minutes - Extended ‘cool down’ test: 12 hours.
Charging is suspended and the voltage is monitored.
If only the green LED (voltage above 12.7V) is flashing after 30 minutes the test is extended to12hours.
The extended test will expose suspect batteries that may seem to hold charge (following recovery), but lose power due to irreversible internal damage once the temperature lowers down to normal.
AGM batteries are expected to remain above 12.7V (green LED).
STD batteries are expected to remain above 12.6V (green / yellow LED).
Charge maintenance: during alternate 30 minute periods, at a float limit of 13.6V the battery is offered whatever charge current it needs to sustain it

OptiMate Pro-2

Ideal for

Recommended for all 12V lead-acid batteries 2 to 100Ah.

OptiMate Pro-8

Can be used on 6V and 12V lead-acid batteries

Simply select 6V or 12V to suit your battery, hook it up and the rest is automatic.
Can be used to charge 6V or 12V batteries connected in series without disconnection.

OptiMate Pro-8

Automatic detection & recovery of deep discharged or sulfated batteries

For neglected batteries in a poor state of health, voltage provided is limited to a maximum 22V while the circuit attempts to deliver a small current into the battery.
This step engages automatically for up to 2 hours.

OptiMate Pro-8

Fully charges new batteries within 12 to 24 hours

To ensure complete charge of a battery it delivers a variable pulsed current by reverting to the CHARGE Program for brief periods..
These reversions can occur as many times as is necessary to ensure that the battery has accepted as much charge as its condition will allow.

OptiMate Pro-8

Tests and verifies charge retention by battery

Voltage retention tests are alternated half-hourly when the charger moves to battery maintenance.
Charge maintenance: during alternate 30 minute periods, at a float limit of 13.6V the battery is offered whatever charge current it needs to sustain it against any small connected loads or power leakage and against natural self discharge.

OptiMate Pro-8

Charging Amps

1 Amp of constant current available at each of 8 banks – from 2V to 14.3V

OptiMate Pro-8

Charging Stages

Battery diagnosis / Desulfation and recovery / Bulk charge / Charge verification / Maintenance program that includes a battery test.

OptiMate Pro-8

Desulfation Stages

All batteries lose charge when stored, discharge is speeded up when the battery is in the vehicle. Sulfation develops if a battery is left discharged for too long. Sulfation causes the battery to lose voltage and capacity, and the ability to accept a charge. The lost capacity cannot be returned by a standard smart charger, instead it quickly and incorrectly shows the battery as fully charged. OptiMate detects sulfation, then applies "first aid" desulfation - carefully controlled higher voltage at low current - for up to 2hours. When the battery is ready to accept charge, bulk charge starts.

IMPORTANT: OptiMate PRO8 desulfation mode works best with the battery disconnected from the vehicle, It`s smart control inhibits desulfation mode if vehicle electronics is detected. During long term charge maintenance mode a frequent desulfating pulse prevents sulfation from re-occurring.

OptiMate Pro-8

Microprocessor

Smart Control - Electronic controller with battery saver and test functions, for precise voltage and current delivery.

OptiMate Pro-8

Test Results

OptiMate PRO8 tests & confirms if a battery can retain sufficient voltage to crank an engine before it engages long term maintenance mode. A battery unable to hold charge or if excessive discharge is detected during long term maintenance charging the RED TEST LED will light. Long term maintenance charging continues even with a RED test light.
Voltage retention tests are alternated half-hourly when the charger moves to battery maintenance.
Charge maintenance: during alternate 30 minute periods, at a float limit of 13.6V the battery is offered whatever charge current it needs to sustain it against any small connected loads or power leakage and against natural self discharge.

OptiMate Pro-8

Ideal for

Recommended for all 12V lead-acid batteries 2 to 50Ah.
The content above is only for North American countries. Select your region at the top right of the screen.